Heat & Glo • Soho-CE • 2111-900 Rev. D • 6/07
24
11
11 Finishing

A. Facing Material

Figure 11.1 Noncombustible Facing Diagram
Fire Risk.
Finish all edges and fronts to clearances and
speci cations listed in manual.
• Black metal appliance front may be covered with
noncombustible material only.
• Do NOT overlap combustible materials onto appliance
front.
Install combustible materials up to speci ed clearances
on top, front and side.
Seal joints between the nished wall and appliance top
and sides using only a 150º C minimum sealant.
NON-COMBUSTIBLE ZONE
FINISH WALL MATERIAL MAY BE
COMBUSTIBLE - TOP AND SIDES
20.3 cm
74 cm
0 cm
0 cm
0 cm

B. Mantel Projections

No mantels are allowed when using Studio-CE fronts.
Risk of Fire
• Non-combustible clearances MUST be
maintained.
Sheetrock, wood or other combustibles must
NOT be used as sheathing or facing in the
non-combustible zone.
• See Section 11 for proper clearances.
• See Section 1 for combustible/non-combustible
de nitions.
WARNING
WARNING
Figure 11.2 Minimum vertical and maximum horizontal
dimensions of combustibles above appliance
when using the DF-SOHOCE-BK dress guard.
12.7
17.8
10.2
OPENING OF FIREPLACE
7.6
12.7
20.3
30.5
5.1
22.9
25.4
27.9
15.2
2.6
40.7
15.2
17.8
20.3
22.9
25.4
27.9
30.5
33.0
35.6
38.1
Note: All dimensions are shown in centimeters