Top Vent - Vertical Termination - (continued)

Two Elbows

Note: A 6 in. (152 mm) section of straight flue must be attached to the heater before a 90° elbow.

USE SLP SERIES COMPONENTS ONLY

V2

 

V1

H1 Maximum

V2

V1 + V2 Min.

Elbow only

Not allowed

*

*

*

6 in.

152 mm

2 ft.

610 mm

*

*

*

1 ft.

305 mm

4 ft.

1.22 m

*

*

*

2 ft.

610 mm

6 ft.

1.83 m

*

*

*

3 ft.

914 mm

8 ft.

2.44 m

*

*

*

4 ft.

1.22 m

12 ft.

3.66 m

*

*

*

5 ft.

1.52 m

16 ft.

4.88 m

*

*

*

V1 + V2 + H1 = 36 ft. (10.97 m) Maximum

*No specific restrictions on this value EXCEPT V1 + V2 cannot exceed 32 ft. (9.75 m)

H1

V1

Figure 7.10

32