Heat & Glo LifeStyle 550TRSI-AUF Finishing, A. Mantel and Wall Projections, B. Facing Material

Models: 550TRSI-AUF

1 80
Download 80 pages 27.78 Kb
Page 63
Image 63
13 Finishing

13 Finishing

A. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear- ances as specified. Framing closer than the minimums list- ed must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc.)

Combustible Mantels

 

 

 

305

 

 

 

 

279

 

NON-COMBUSTIBLE

 

 

254

 

 

229

 

BOARD

 

203

 

 

 

178

 

305

 

152

 

 

279

127

 

254

 

102

 

 

229

 

76

 

 

203

 

 

 

127 152178

 

51

76

102

 

51

 

 

 

 

 

 

 

 

 

TOP FRONT EDGE

OF FIREPLACE

Note: All measurements in millimeters.

Note: Measurement is taken from top of the opening, NOT the top of the fireplace.

Figure 13.1 Minimum Vertical and Maximum Horizontal

Dimensions of Combustibles

Combustible Mantel Legs or Wall Projections

*Add 1/2 in. (13 mm for rear vent)

B. Facing Material

Metal front faces may be covered with non-combustible materials only.

Facing and/or finishing materials must not interfere with air flow through louvers, operation of louvers or doors, or access for service.

Facing and/or finishing materials must never overhang into the glass opening.

Observe all clearances when applying combustible materials.

Seal joints between the finished wall and appliance top and sides using a 300º F (149º C) minimum sealant.

WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Overlapping materials could ignite and will interfere with proper operation of doors and louvers.

B

A

TOP VIEW

2-7/8 in.*

(73 mm)

MINIMUM

1/2 in.* A. Mantel and Wall Projections (13 mm)

MINIMUM

3 ft. (914 mm) MAXIMUM

 

 

A

B

550TRSI-AUF

Inches

36

37

550TRSILP-AUF

millimeters

816

940

Figure 13.3 Noncombustible Facing Diagram

Figure 13.2 Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening)

Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF2079-980 Rev. N • 5/12

63

Page 63
Image 63
Heat & Glo LifeStyle 550TRSI-AUF Finishing, A. Mantel and Wall Projections, B. Facing Material, Combustible Mantels