Heat & Glo LifeStyle 550TRSI-AUF owner manual Troubleshooting continued, Symptom, Possible Cause

Models: 550TRSI-AUF

1 80
Download 80 pages 27.78 Kb
Page 69
Image 69

Troubleshooting (continued)

Symptom

Possible Cause

Corrective Action

 

 

 

4. Pilot lights but contin-

A. A shorted or loose connection in flame

Verify all connections to wiring diagram in manual. Verify

ues to spark, and main

sensing rod.

connections underneath pilot assembly are tight. Verify

burner will not ignite.

 

flame sense or igniter wires are not grounding out to metal

(If the pilot continues

 

chassis, pilot burner, pilot enclosure or screen if present, or

to spark after the

 

any other metal object.

pilot flame has been lit,

 

 

B. Poor flame rectification or contaminated

With fixed glass assembly in place, verify that flame is en-

flame rectification has

flame sensing rod.

gulfing flame sensing rod on left side of pilot hood. Flame

not occurred.)

 

sensing rod should glow shortly after ignition. With a multi-

 

 

 

 

meter, verify that current in series between module and

 

 

sense lead is at least 0.14 microamps. Verify correct pilot

 

 

orifice is installed and gas inlet is set to pressure specifi-

 

 

cations. Polish flame sensing rod with fine steel wool to

 

 

remove any contaminants that may have accumulated on

 

 

flame sensing rod.

 

 

 

 

C. Module is not grounded.

Verify module is securely grounded to metal chassis of ap-

 

 

pliance. Verify that wire harness is firmly connected to the

 

 

module.

 

 

 

 

D. Damaged pilot assembly or contami-

Verify that ceramic insulator around the flame sensing rod

 

nated flame sensing rod.

is not cracked, damaged, or loose. Verify connection from

 

 

flame sensing rod to white sensor wire. Polish flame sens-

 

 

ing rod with fine steel wool to remove any contaminants

 

 

that may have accumulated on flame sensing rod. Verify

 

 

continuity with a multi-meter with ohms set at lowest range.

 

 

Replace pilot if any damage is detected.

 

 

 

5. Carbon Deposition

A. Log Placement

Verify placement and assure flame is not excessively

 

 

impinging on log.

 

B. Shutter Setting

Check to assure correct shutter setting for your model and

 

 

gas type.

 

C. Gas Type

Assure correct fuel matches unit gas model and components.

 

 

 