Heat & Glo LifeStyle 550TRSI-AUF B. Vent Components Diagrams continued, 12 in, Effective, Length

Models: 550TRSI-AUF

1 80
Download 80 pages 27.78 Kb
Page 76
Image 76
 8 in. (203 mm)

B. Vent Components Diagrams (continued)

Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B will be required.

SLP-TRAP 8 in.Horizontal Termination Cap (203 mm)

Heat

Shield

15-1/8 in.

(384 mm)

12 in.

Max

Effective

(305 mm)

Length

 

 

SLP-TRAP

 

Horizontal Termination Cap

Term Cap

Minimum

Maximum

Effective Length

Effective Length

 

Trap1

3-1/8 in.

4-3/4 in.

79 mm

121 mm

 

Trap2

5-1/4 in.

9-1/4 in.

133 mm

235 mm

 

SLP-SNKD

SLP-CCS-BK

SLP-TVHW

 

DVP-FBHT

Cathedral Ceiling

Vertical

 

Horizontal

Snorkel

 

Support Box-Black

Termination Cap

Termination Cap

Termination Cap

 

 

 

 

 

 

 

 

26 in.

 

 

 

 

660 mm

 

SL-2DVP

DVP-2SL

 

DVP-HSM-B

 

Adapter

Adapter

Extended Heat Shield

 

 

SLP-DCF-BK

SLP-WT-BK

 

DVP-HE

Ceiling Firestop

Wall Thimble-Black

 

Heat Exchanger

Black

 

 

Figure 16.7 SLP Series Vent Components

 

 

 

 

 

 

76

Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF2079-980 Rev. N • 5/12

 

Page 76
Image 76
Heat & Glo LifeStyle 550TRSI-AUF B. Vent Components Diagrams continued, 8 in.203 mm Heat Shield 15-1/8in 384 mm, 12 in