Heat & Glo LifeStyle 6000GCF-IPILP Top Vent - Horizontal Termination, Three Elbows, H2, continued

Models: 6000GCF-IPI 6000GCF-IPILP

1 56
Download 56 pages 39.21 Kb
Page 14
Image 14
1. Top Vent - Horizontal Termination

1. Top Vent - Horizontal Termination

- (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Three Elbows

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V1 Minimum

H1 Maximum

V2 Minimum

H2 Maximum

V1 + V2 Minimum

H1 + H2 Maximum

6 in.

152 mm

3 ft

914 mm

1 ft

 

305 mm

3 ft

914 mm

1-1/2 ft

457 mm

6 ft

1.8 m

1 ft

305 mm

3 ft

914 mm

1 ft

 

305 mm

3 ft

914 mm

2 ft

607 mm

6 ft

1.8 m

 

 

 

 

 

 

 

 

 

 

 

 

 

2 ft

610 mm

6 ft

1.8 m

2 ft

 

610 mm

6 ft

1.8 m

4 ft

1.4 m

12 ft

3.7 m

3 ft

914 mm

9 ft

2.7 m

3 ft

 

914 mm

9 ft

2.7 m

6 ft

1.8 m

18 ft

5.5 m

 

H1 + H2 = 20 ft (6.1 m) Max.

V1 + V2 + H1 + H2 = 50 ft (15.2 m) Max.

V1 = 6 inches (152 mm) Min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H2

V2

H1V1

Figure 5.5

14

Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP2110-900 Rev. F • 6/08

Page 14
Image 14
Heat & Glo LifeStyle 6000GCF-IPILP Top Vent - Horizontal Termination, Three Elbows, H2, continued, V1 Minimum, H1 Maximum