Heat & Glo LifeStyle 6000GCF-IPILP owner manual B. Vent Components Diagrams, 2 DVP vent components

Models: 6000GCF-IPI 6000GCF-IPILP

1 56
Download 56 pages 39.21 Kb
Page 48
Image 48
B. Vent Components Diagrams

B. Vent Components Diagrams

 

 

Pipe

Effective Length

10-1/2 in.

 

 

Effective

Inches

Millimeters

(267 mm)

45°

 

 

 

Height/Length

DVP4

4

102

 

 

 

 

DVP6

6

152

 

 

 

 

DVP12

12

305

4-7/8 in.

 

 

 

DVP24

24

610

( 276 mm)

 

 

 

 

10-7/8 in.

 

 

DVP36

36

914

 

 

DVP Pipe (see chart)

 

(276 mm)

 

DVP48

48

1219

DVP45 (45 Elbow)°

 

 

 

 

DVP6A

3 to 6

76 to 152

 

 

 

 

 

 

DVP12A

3 to 12

76 to 305

 

 

 

 

DVP12MI

3 to 12

76 to 305

 

 

 

 

DVP24MI

3 to 24

76 to 610

 

 

 

 

 

 

 

 

11-3/8 in.

 

 

 

 

 

 

(289 mm)

 

10 in.

 

 

 

 

 

 

(254 mm)

10 in.

1 in.

 

 

 

 

(254 mm)

 

 

 

 

(25 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-3/8 in.

 

24 in.

 

 

 

 

(187 mm)

 

 

 

 

 

 

 

(610 mm)

 

 

 

 

1-1/4 in. (32 mm)

 

 

 

 

 

 

 

 

 

 

 

9-1/4 in.

 

 

 

 

 

 

(235 mm)

1/2 in. TYP

 

 

 

 

 

13-1/4 in.

(13 mm)

 

 

 

 

 

 

 

 

 

 

 

(337 mm)

 

 

DVP-AS (Attic Shield)

DVP-FS (Ceiling Firestop)

DVP90ST (90° Elbow)

 

 

 

 

 

 

 

 

 

 

12 in.

1 in.

 

 

 

 

 

(305 mm)

(25 mm)

 

10 in.

1- 1/2 in.

 

 

 

8 in.

 

 

 

 

(203 mm)

 

(254 mm)

(38 mm)

 

14 in.

 

 

 

 

 

 

 

 

 

UP

 

 

(356 mm)

 

 

 

 

 

 

 

 

5 in.

12 in.

 

 

 

 

 

(127 mm)

(305 mm)

 

 

 

 

 

 

 

 

 

6 in.

 

 

 

 

 

 

(152 mm)

 

 

DVP-HVS (Vent Support)

 

 

 

DVP-WS (Wall Shield Firestop)

 

Figure 16.2 DVP vent components

 

 

 

 

 

48

Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP2110-900 Rev. F • 6/08

 

Page 48
Image 48
Heat & Glo LifeStyle 6000GCF-IPILP owner manual B. Vent Components Diagrams, 2 DVP vent components