E. Junction Box Installation

If the box is being wired from the appliance:

Remove the screw attaching the junction box to the outer shell, rotate the junction box inward to disengage it from the outer shell (see Figure 10.2).

Pull the electrical wires from outside the appliance through this opening into the valve compartment.

Loosen the two screws on the Romex connector (not included with unit), feed the necessary length of wire through the connector and tighten the screws.

Make all necessary wire connections to the receptacle and assemble the receptacle and cover to the junction box.

 

Romex

 

Connector

 

14/2WG

 

Cover Plate

 

outside firebox

WHT

 

BLK

 

WHT

 

BLK

Copper

 

GRN wire

ground attached

to GRN screw with

inside box

GRN wire

 

NOTE: Do NOT wire

Figure 10.2 Junction Box Detail

110VAC to wall switch.

 

F. Wall Switch Installation for Fan (Optional)

If the box is being wired to a wall mount-

 

 

ed switch for use with a fan (See Fig-

 

 

ure 10.4):

 

SWITCH

The power supply for the appliance must

 

MINIMUM 14-3 AWG

 

 

be brought into a switch box.

WITH GROUND

 

 

 

 

• The power can then be supplied from

Red

Black

Black

 

the switch box to the appliance using a

White

White

 

Green

Green

 

minimum of 14-3 with ground wire.

JUNCTION BOX

 

At the switch box connect the black (hot)

Red Black White Green

 

 

wire and red (switch leg) wire to the wall

 

 

 

POWER

 

switch as shown.

 

SUPPLY WIRES

 

 

 

At the appliance connect the black (hot),

 

SWITCH BOX

 

 

 

white (neutral) and green (ground) wires

 

 

 

to the junction box as shown.

 

 

• Add a 1/4 inch insulated female connector

 

 

 

to the red (switch leg) wire, route it through

Red

 

 

the knockout in the face of the junction

 

 

 

box, and connect to the top fan switch

 

 

 

connector (1/4 inch male) as shown.

Figure 10.4 Junction Box Wired to Wall Switch

 

 

Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP2110-900 Rev. F • 6/08