2 Getting Started
A. Design and Installation Considerations | C. Inspect Appliance and Components | |
Heat & Glo direct vent gas appliances are designed to | WARNING | |
operate with all combustion air siphoned from outside of | ||
the building and all exhaust gases expelled to the outside. | Inspect appliance and components for damage. | |
No additional outside air source is required. | ||
| Damaged parts may impair safe operation. | |
CAUTION | • Do NOT install damaged components. | |
• Do NOT install incomplete components. | ||
| ||
| • Do NOT install substitute components. | |
Check building codes prior to installation. | Report damaged parts to dealer. |
•Installation MUST comply with local, regional, state and national codes and regulations.
| • Consult local building, fire officials or authorities having jurisdic- | • | Carefully remove the appliance and components from | |||
| tion about restrictions, installation inspection, and permits. |
| the packaging. | |||
|
|
|
| • The vent system components and trim doors are shipped | ||
When planning an appliance installation, it’s necessary to |
| in separate packages. | ||||
determine the following information before installing: | • | The gas logs may be packaged separately and must be | ||||
• | Where the appliance is to be installed. |
| field installed. | |||
• | The vent system configuration to be used. | • | Report to your dealer any parts damaged in shipment, | |||
• | Gas supply piping. |
|
| particularly the condition of the glass. | ||
| • | Read all of the instructions before starting the insta- | ||||
• | Electrical wiring. |
| ||||
|
| llation. Follow these instructions carefully during the | ||||
• | Framing and finishing details. |
| ||||
| installation to ensure maximum safety and benefit. | |||||
• | Whether optional |
|
|
| ||
| wall switch, or remote |
|
| WARNING | ||
|
|
|
|
|
| |
|
|
| WARNING |
|
| Hearth & Home Technologies disclaims any |
|
|
|
|
| responsibility for, and the warranty will be voided | |
| Keep appliance dry. |
|
| by, the following actions: | ||
|
| • | Installation and use of any damaged appliance or vent | |||
| • | Mold or rust may cause odors. |
| |||
|
|
| system component. | |||
| • | Water may damage controls. |
|
| ||
|
| • | Modification of the appliance or vent system. | |||
|
|
|
|
| ||
|
|
|
|
| • | Installation other than as instructed by Hearth & Home |
B. Tools and Supplies Needed |
|
| Technologies. | |||
Before beginning the installation be sure that the following |
| • Improper positioning of the gas logs or the glass door. | ||||
| • Installation and/or use of any component part not approved | |||||
tools and building supplies are available. |
| |||||
|
| by Hearth & Home Technologies. | ||||
|
|
|
|
|
| |
Reciprocating saw | Framing material |
| Any such action may cause a fire hazard. | |||
Pliers |
| Hi temp caulking material |
|
|
| |
Hammer |
| Gloves |
|
|
| |
Phillips screwdriver | Framing square |
|
|
| ||
Flat blade screwdriver | Electric drill and bits (1/4 in.) |
|
|
| ||
Plumb line |
| Safety glasses |
|
|
| |
Level |
| 1/2 - 3/4 inch length, #6 or #8 | ||||
Manometer |
| Voltmeter |
|
|
| |
Tape measure |
| Noncorrosive leak check solution |
|
|
|
One 1/4 inch female connection (for optional fan).
6 | Heat & Glo • |