4. Utilize projector – Advanced -

4.8 Command Control via the Network

<RXFDQFRQ¿JXUHDQGFRQWUROWKHSURMHFWRUYLDWKHQHWZRUNXVLQJ56&

commands.

Communication Port

The following two ports are assigned for the command control. TCP #23

TCP #9715

NOTE • Command control is not available via communication port (TCP #9716) that is used for the e-Shot transmission function.

Command Control Settings

( 25)

&RQ¿JXUHWKHIROORZLQJLWHPVIURPDZHEEURZVHUZKHQFRPPDQGFRQWUROLVXVHG

Example: If the IP address of the projector is set to 192.168.1.10:

1)Enter [http://192.168.1.10] into the address bar of the web browser.

2)Enter the Administrator ID and Password and click [Logon].

3)Click [Port settings] on the main menu.

4)Click the [Enable] check box to open [Network Control Port (Port: 23)] to use TCP #23. Click the [Enable] check box for the [Authentication] setting when authentication is required, otherwise clear the check box.

5)Click the [Enable] check box to open [Network Control Port (Port: 9715)] to use TCP #9715. Click the [Enable] check box for the [Authentication] setting when authentication is required, otherwise clear the check box.

6)Click the [Apply] button to save the settings.