4. Utilize projector – Advanced -

4.5 Projector management via SNMP

When SNMP is enabled, the projector is able to send Failure/Warning Alerts to a VSHFL¿HG3&

NOTE • It is recommended that SNMP functions be carried out by a network administrator.

SNMP management software must be installed on the computer to monitor the projector via SNMP.

SNMP settings

( 25)

&RQ¿JXUHWKHIROORZLQJLWHPVYLDDZHEEURZVHUWRXVH6103

Example: If the IP address of the projector is set to 192.168.1.10:

1)Enter [http://192.168.1.10] into the address bar of the web browser.

2)Enter the Administrator ID and Password and click [Logon].

3)Click [Port Settings] on the main menu.

4)Click the [Enable] check box to open the SNMP Port.

Set the IP address to send the SNMP Trap to when a Failure/Warning occurs.

NOTE ‡$1HWZRUN5HVWDUWLVUHTXLUHGDIWHUWKH61037UDSFRQ¿JXUDWLRQ settings have been changed. Click [Network Restart]DQGFRQ¿JXUHWKH following items.

5)Click [Security Settings] on the main menu.

6)Click [SNMP] and set the Community Name on the screen that is displayed.

NOTE • A Network Restart is required after the Community Name has been changed.

Click [Network Restart]DQGFRQ¿JXUHWKHIROORZLQJLWHPV

 &RQ¿JXUHWKHVHWWLQJVIRU7UDSWUDQVPLVVLRQRI)DLOXUHV:DUQLQJV&OLFN [Alert Settings] on the main menu and select the Failure/Warning item to be FRQ¿JXUHG

8)Click the [Enable] check box to send out the SNMP trap for Failures/Warnings. Clear the [Enable] check box when SNMP trap transmission is not required.

9)Click the [Apply] button to save the settings.