Hitachi NT50AGF manual Testing The Nailer, Danger

Models: NT50AGF

1 102
Download 102 pages 1.51 Kb
Page 18
Image 18
TESTING THE NAILER

English

TESTING THE NAILER

— 18 — DANGER

Operators and others in work area MUST wear safety glasses with side shields which conforms to ANSI Z87.1 specifications.

Manual background WARNING

Never use Nailer unless safety trigger is working properly Manufacturer recommends before each use, check the Set Screw on the Ram Head to make sure the Ram Head is not loose.

Manufacturer recommends before each use, check all Screws and Nuts to make sure they are tight and have not “jarred loose” from vibration and use. (Shoe, Shoe Base and Pad, Magazine, Magazine Retainer Bracket, Handle, etc.).

Manufacturer recommends before each use, check the Driver Blade tip for deformation & breakage to prevent improper driving of Nails and/or to prevent damage to the Nailer and Flooring.

Before actually beginning the nailing work, test the Nailer by using the check list below.

Conduct the tests in the following order.

If abnormal operation occurs, stop using the Nailer and contact a Hitachi authorized service center immediately.

1)Adjust the air pressure to 90 psi (6.2 bar, 6.3 kgf/cm2)

Connect the air hose.

Do not load any nails in the Tool

The Tool must not leak air.

2)Pull the safety trigger.

The Tool must not operate.

3)Remove the finger from the trigger and contact the ram cap.

The Tool must not operate.

4)First, pull the safety trigger. Next, contact the ram cap.

The Tool must operate.

— 18 —

Page 18
Image 18
Hitachi NT50AGF manual Testing The Nailer, Danger