English
Operator Troubleshooting
Most minor problems can be resolved quickly and easily using the table below.
If problems persist, contact a Hitachi authorized service center for assistance.
PROBLEM OR | CAUSE | CORRECTIVE ACTION |
QUESTION |
|
|
|
|
|
Nailer is | Air pressure too | Set air pressure to |
Jamming | low |
|
|
|
|
| Using air compres- | Smaller air compressors sup- |
| ||
| sor that is too small | plying a lower than recom- |
|
| mended volume of air, may |
|
| require you to wait for the |
|
| compressor to ‘catch up’. If air |
|
| compressor is running you may |
|
| need to wait until it cuts off to |
|
| continue nailing. |
|
|
|
| Consistently hitting | Only Tap the Ram to operate |
| ||
| the Ram too hard. | the Nailer. If you are raising the |
|
| hammer more than 12” above |
|
| the ram head you are more |
|
| likely to hit the ram too hard. |
|
|
|
| Tip of Driver Blade | Contact Hitachi for replace- |
| ||
| broken. (Ref. #58) | ment. |
|
|
|
| Access Gate may | Check Access Gate (Ref. #22) to |
| ||
| not be closed prop- | ensure it’s properly closed. |
| erly. (Ref. #22) |
|
|
|
|
| More than one nail | Check Rail (Ref. #26) for wear |
| ||
| entering the driving | on the end. If worn, turn rail |
| chamber. | around to use other end in |
|
| Guide or replace the rail. Make |
|
| sure pusher provides positive |
|
| pushing force on the nail clip to |
|
| prevent nails from turning. |
|
|
|
Nailer is not | Air pressure too | Set air pressure to |
always driving | low. |
|
a nail |
|
|
|
|
|
| Using air compres- | Smaller air compressors sup- |
| ||
| sor that is smaller | plying a lower than recom- |
| than recommend- | mended volume of air, may |
| ed. | require you to wait for the |
|
| compressor to ‘catch up’. If air |
|
| compressor is running you may |
|
| need to wait until it cuts off to |
|
| continue nailing. |
|
|
|
|
| - Continued - |