Hitachi NT50AGF manual Maintenance And Inspection, Clearing a Jam

Models: NT50AGF

1 102
Download 102 pages 1.51 Kb
Page 26
Image 26
MAINTENANCE

English

MAINTENANCE

Note:

The information contained in this Manual is designed to assist you in the safe maintenance of the Nailer.

Some illustrations in this Manual may show details or at- tachments that differ from those on your own Nailer.

MAINTENANCE AND INSPECTION

Read section titled “SAFETY” (page 4-9)

MAINTENANCE AND INSPECTION WARNING

Disconnect air hose and remove all nails from Nailer when:

1)doing maintenance and inspection; and

2)clearing a jam.

1. Clearing a Jam

In the event of a jam, the Gate (Ref. No. 22) can be opened by unscrewing the two Gate Screws and releasing the Gate. (See Figures 1 and 2) (The Shoe does not have to be removed to remove and replace the Gate.) Follow instructions below. IMMEDIATELY DISCONNECT from power source until jam is cleared!

Remove all Nails in the Magazine.

DO NOT PRY OPEN THE GATE. Unscrew the Gate Screws 1-2 turns. Lift and pull the Gate downward as shown and remove the Gate from over the Screws through the slots in the Gate as shown in Figure 1.

Figure 1

— 26 —
Page 26
Image 26