Depress Safety Trigger, and strike Ram Head of the NT50AGF Pneu- matic Flooring Nailer with the Face Nailing Shoe installed.

After tapping the Ram Head, the actuating cycle of the NT50AGF Pneumatic Flooring Nailer drives one nail into the Flooring.

When the nail has been completely driven, the NT50AGF Pneumat- ic Flooring Nailer will automatically reset, and is ready to be moved to the next position and drive another nail.

Be careful not to drive one nail on top of another. Damage to the Nailer might result or injury from sparks or a sliver of metal that might break away if this should occur.

If a nail is driven on top of another or a jam occurs, refer to the sec- tion of the manual on “Clearing a Jam”.

Slide the NT50AGF Pneumatic Flooring Nailer along the Flooring to the location at which you desire to drive the next nail.

Continue until four (4) rows of Flooring have been Face Nailed.

Remove the Face Nailing Shoe Accessory from the NT50AGF Pneu- matic Flooring Nailer and install the Tongue and Groove Nailing Shoe (See Shoe Changing Section).

Place the groove of the fifth row of Flooring over the tongue of the fourth row of Flooring and tighten using the Hammer. Depress the Safety Trigger, and tap Ram Head of the NT50AGF Pneumatic Floor- ing Nailer with the Tongue and Groove Nailing Shoe installed.

Slide the NT50AGF Pneumatic Flooring Nailer along the tongue of the Flooring to the location at which you desire to place the next nail.

Continue until you have completely nailed all but the last five (5) rows of Flooring.

Remove the Tongue and Groove Nailing Shoe from the NT50AGF Pneumatic Flooring Nailer and install the Face Nailing Shoe (See Shoe Changing Section).

Install and nail in place the remaining five (5) rows of Flooring us- ing the NT50AGF Pneumatic Flooring Nailer with the Face Nailing Shoe installed.