Hitachi NT50AGF manual

Models: NT50AGF

1 102
Download 102 pages 1.51 Kb
Page 32
Image 32
— 32 —

English

Nails are not be-

The Piston Cushion

Contact Hitachi for replace-

ing counter sunk

(Ref. #10) could be

ment.

into wood and

damaged prevent-

 

are left sticking

ing the Piston (Ref.

 

out of wood.

#56) from complet-

 

(cont.)

ing full stroke.

 

 

 

 

Nailer does not

This is a safety

The Nailer is not supposed

operate when

feature

to operate when the Trigger

trigger is pulled.

 

is pulled. In order to operate

 

 

the Nailer, the Trigger must be

 

 

pulled and the Ram Head (Ref.

 

 

#47) tapped with the hammer,

 

 

in that order.

 

 

 

Ram is stuck in

Air pressure too

Set air pressure to 100-115 PSI

down position

low.

 

 

 

 

 

Driver Blade (Ref.

Contact Hitachi for replace-

 

 

#58) could be bent

ment.

 

 

 

 

Oil could have been

Contact Hitachi for replace-

 

 

used in the tool

ment.

 

 

 

 

Cylinder Cushion

Contact Hitachi for replace-

 

 

Ring (Ref. #5) could

ment.

 

be loose or dam-

 

 

aged or has been

 

 

installed upside

 

 

down.

 

 

 

 

Tool partially

Main Valve (Ref.

Contact Hitachi for replace-

operates when

#41) is not seating

ment.

air hose is con-

in Valve Housing

 

nected

(Ref. #46).

 

 

 

 

 

O-Rings on the

Contact Hitachi for replace-

 

 

Discharge Valve

ment.

 

(Ref. #11) may be

 

 

damaged.

 

 

 

 

 

Discharge Valve

Contact Hitachi for replace-

 

 

Springs (Ref. #9)

ment.

 

not aligned

 

 

 

 

 

Cylinder Exhaust

Contact Hitachi for replace-

 

 

Valve Screw (Ref.

ment.

 

#50) may be loose.

 

 

 

 

Nailer partially

Main Valve Lip Seal

Contact Hitachi for replace-

operates when

(Ref. #41) is not

ment.

trigger is pulled

sealing

 

and before Ram

 

 

is struck

 

 

 

 

 

— 32 —