English
Recommended Air Compressor Specifications
•HP: 1 1/2 HP or greater.
•Compressor Rated at 150 PSI Max. or greater.
•Accumulator Tank Capacity: 4 Gallons or greater
•Pressure Regulator: Set operating pressure at 90 - 110 PSI.
•SCFM @ 100 PSI: 4.6 CFM
•Pressure Switch Trip On: 110 PSI (± 5)
•Pressure Switch Trip Off: 135 PSI (± 5)
ALWAYS follow the Air Compressor Manufacturers’ recommen- dations for adjustments.
2. Filter-Regulator-Lubricator
There should be an
3. Air Hose
3/8” ID is recommended. Air supply hoses should have a mini- mum working pressure rating of 150 PSI (10.4 bar 10.6 kgf/cm2) or 150 percent of the maximum pressure produced in the power source, whichever is higher.
4. Hose Coupling
Any configuration of quick connect fittings with either a 3/8” NPT thread or a combination of a 1/4 NPT thread fitting and 3/8 – 1/4 NPT reducer. The fitting must be capable of discharging tool air pressure when disconnected from the air supply.
5. Air Consumption
The Tool requires 4.6 cubic feet per minute of free air to operate at the rate of 60 fasteners per minute @ 90 PSI. Take the actual rate at which the tool will be run to determine the amount of air required. For instance, if your fastener usage averages 30 fasteners per minute, you need 50% of the tool’s CFM of free air which is required to operate the tool at 60 fasteners per minute.
6. Operating Pressure
90 to 110 PSI Select the operating pressure within this range for best fastener performance. DO NOT EXCEED 120 PSI.