DRAIN VALVE HANDLE

Remove the wire rack and install the overflow and skim tubes, wide side down, in the drains at the bottom of the rotisserie (Fig. 4); placement is interchangeable. Replace the wire rack.

Remove the drain handle from its shipping location on the drain valve and install it properly on the drain valve stem (Fig. 5).

DRAIN VALVE HANDLE

OVERFLOW TUBE

DRAIN VALVE STEMSKIM TUBE

PL-41658-1

DRAIN VALVE STEM

PL-41659-1

Fig. 4

Fig. 5

LEVELING

If the rotisserie oven is equipped with casters (standard), move the rotisserie oven to its final installed position and lock the front casters; back casters are nonlocking. Casters are nonadjustable; therefore, the floor must be level to avoid experiencing cooking problems.

If the rotisserie oven is equipped with adjustable feet (optional), move the rotisserie oven to its final installed position. Place a spirit level on top of the rotisserie oven and turn the adjustable feet in or out to level the rotisserie oven front to back and side to side.

TETHER CONNECTION

When equipped with casters, the gas connection must be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 (latest edition) or Connectors for Moveable Gas Appliances, (CAN/CGA-6.16) and must be made with a quick-disconnect device that complies with the Standard for Quick- Disconnect Devices for Use With Gas Fuel, ANSI Z21.41 (latest edition) or Quick-Disconnect Devices for Use With Gas Fuel (CANI-6.9). Tether the rotisserie oven using the hole provided on the left side of machine next to the gas connection (Fig. 6).

If disconnection of the tether is necessary, turn off the gas and water supplies before disconnection. After returning the rotisserie oven to its original position, reconnect the tether before turning the gas and water supplies back on.

HOLE

FOR

TETHER

PL-41656-1

Fig. 6

– 7 –