Honeywell EN2H-0221GE51 R0808 service manual Unlimited enable during start-up relief

Models: EN2H-0221GE51 R0808

1 258
Download 258 pages 27.36 Kb
Page 134
Image 134

Hydraulic Components

SDC / DHC

 

 

Time delay stage II Enabling of stage II (full load stage) is controlled not only by the switching differentials but also by a time delay. In this way, stage

IIremains disabled for the set delay so that stage I will be active longer. This function is only effective during the start-up phase (when there is demand for both stages). When stage I is in base- load operation and stage II in adjustment operation (covering excess heat demand), the latter is switched on immediately when the demand arises.

NOTE In cascade mode, this setting would be superseded by the cascade setting and is therefore not available.

Enabling mode stage II The parameter "Enabling mode full-load stage" allows changing the effect of a time delay stage II setting during the start-up phase below the heat generator minimum temperature limit.

Unlimited enable during start-up relief

Both stages are in unlimited operating during start-up.

Time-out during start-up relief

Stage II is switched on after the set time delay acc. to time delay stage II:

NOTE In cascade mode, this setting would be superseded by the cascade setting and is therefore not available.

Hot-waterThe function "hot-water loading mode stage 1-2" allows defining loading mode of the loading mode for the hot-water heater with 2-stage or 2 x

stage II single-stage heat generators. The following options are available:

2-stage hot-water circuit loading with delayed enabling of stage II acc. to time delay stage II

Unlimited 2-stage hot-water circuit loading

Hot-water loading with stage I only; stage II disabled

NOTE In cascade mode, this setting would be superseded by the cascade setting and is therefore not available.

See also 5.4.6 "Heat generator" menu (HEAT GENER., pg. 99

Outside temperature When the actual outside temperature exceeds the set limit, all disable demand on the heat generator is disabled within a device. The

heating circuits continue operating, but the heat generator will not be switched on. The preset minimum burner running times are

134

EN2H-0221GE51 R0808

Page 134
Image 134
Honeywell EN2H-0221GE51 R0808 service manual Unlimited enable during start-up relief, Time-out during start-up relief

EN2H-0221GE51 R0808 specifications

The Honeywell EN2H-0221GE51 R0808 is a versatile and efficient solution designed to enhance HVAC (Heating, Ventilation, and Air Conditioning) systems in commercial and residential settings. This device stands out in the marketplace due to its robust features, technologies, and characteristics that cater to a variety of applications.

One of the primary features of the EN2H-0221GE51 R0808 is its user-friendly interface, which allows for easy configuration and management. The device is equipped with an intuitive display that provides real-time data, enabling users to monitor system performance at a glance. This functionality not only simplifies operation but also enhances user engagement, making it an ideal choice for both novice and experienced users.

The device employs advanced control technologies, including proportional-integral-derivative (PID) control algorithms. This ensures that the HVAC system operates at optimal efficiency, maintaining the desired temperature while minimizing energy consumption. The precision of the PID control allows for smoother transitions and increased comfort levels within the environment.

Another significant characteristic of the Honeywell EN2H-0221GE51 R0808 is its compatibility with various communication protocols, including Modbus, BACnet, and more. This flexibility facilitates integration with existing building management systems, allowing for comprehensive control over heating and cooling operations. Such interoperability aids in streamlining processes and enhancing system performance.

Durability is also a hallmark of the EN2H-0221GE51 R0808. Constructed with high-quality materials, the device is designed to withstand the rigors of demanding environments. Its sturdy design contributes to longevity and reliability, reducing the need for frequent replacements and maintenance.

Energy efficiency is at the forefront of the Honeywell EN2H-0221GE51 R0808's design. It incorporates features that allow for advanced energy monitoring and reporting, helping users identify potential savings areas. This attention to energy consumption not only promotes sustainability but also leads to significant cost savings over time.

Finally, the EN2H-0221GE51 R0808 supports remote access capabilities, enabling users to control and monitor their systems from anywhere. This feature is particularly beneficial for property managers and business owners, as it allows for swift adjustments and oversight, ensuring that temperature and air quality remain within desired parameters.

In summary, the Honeywell EN2H-0221GE51 R0808 is a sophisticated and reliable solution for HVAC systems. Its user-friendly design, advanced control technologies, compatibility with communication protocols, durability, energy efficiency features, and remote access capabilities make it an outstanding choice for various applications in both commercial and residential scenarios.