Honeywell EN2H-0221GE51 R0808 service manual Solar loading switch-over operation

Models: EN2H-0221GE51 R0808

1 258
Download 258 pages 27.36 Kb
Page 214
Image 214

Hydraulic Components

SDC / DHC

 

 

to support heating during periods when less solar power is available.

To ensure that the solar tank in priority operation (temperature sensing by the sensor of the solar loading switch-over, usually hot-water tank) can be loaded, checks are performed at regular intervals to determine whether sufficient solar power is available (meaning the solar panel temperature is sufficiently high for loading and the set switch-over temperature can be reached).

Diverter valve This function allows switching of a diverter valve according to the load condition of two heat storage tanks (two-point output) so that solar energy can be used to support heating during periods of low solar intake.

Test cycle If the switch-over condition is not fulfilled after a preset time interval of 30 minutes (meaning the temperature in the first-priority tank remains below the set switch-over temperature) and if the loading conditions for the second-priority tank (temperature sensing by the collector tank/buffer sensor, usually buffer tank for heating support) are fulfilled, the solar loading pump (SOP) is temporarily switched off after the time set in the "Solar" menu, parameter 15. During the switch-off time, the differential between the collector flow sensor (SPFS) and the sensor for solar loading switch-over (SLVF) is determined. If the switch-on condition is fulfilled, the first-priority tank is loaded. If the loading condition is not fulfilled after the set time, loading is continued into the lower priority tank as long as the loading conditions are not fulfilled.

These cyclical checks are suspended if the temperature at the solar loading switch-over sensor plus the switch-on differential becomes greater or equal the set final switch-off temperature.

Solar loading switch-over operation

Only a setting option if a solar loading pump is set on the hydraulic level.

214

EN2H-0221GE51 R0808

Page 214
Image 214
Honeywell EN2H-0221GE51 R0808 service manual Solar loading switch-over operation

EN2H-0221GE51 R0808 specifications

The Honeywell EN2H-0221GE51 R0808 is a versatile and efficient solution designed to enhance HVAC (Heating, Ventilation, and Air Conditioning) systems in commercial and residential settings. This device stands out in the marketplace due to its robust features, technologies, and characteristics that cater to a variety of applications.

One of the primary features of the EN2H-0221GE51 R0808 is its user-friendly interface, which allows for easy configuration and management. The device is equipped with an intuitive display that provides real-time data, enabling users to monitor system performance at a glance. This functionality not only simplifies operation but also enhances user engagement, making it an ideal choice for both novice and experienced users.

The device employs advanced control technologies, including proportional-integral-derivative (PID) control algorithms. This ensures that the HVAC system operates at optimal efficiency, maintaining the desired temperature while minimizing energy consumption. The precision of the PID control allows for smoother transitions and increased comfort levels within the environment.

Another significant characteristic of the Honeywell EN2H-0221GE51 R0808 is its compatibility with various communication protocols, including Modbus, BACnet, and more. This flexibility facilitates integration with existing building management systems, allowing for comprehensive control over heating and cooling operations. Such interoperability aids in streamlining processes and enhancing system performance.

Durability is also a hallmark of the EN2H-0221GE51 R0808. Constructed with high-quality materials, the device is designed to withstand the rigors of demanding environments. Its sturdy design contributes to longevity and reliability, reducing the need for frequent replacements and maintenance.

Energy efficiency is at the forefront of the Honeywell EN2H-0221GE51 R0808's design. It incorporates features that allow for advanced energy monitoring and reporting, helping users identify potential savings areas. This attention to energy consumption not only promotes sustainability but also leads to significant cost savings over time.

Finally, the EN2H-0221GE51 R0808 supports remote access capabilities, enabling users to control and monitor their systems from anywhere. This feature is particularly beneficial for property managers and business owners, as it allows for swift adjustments and oversight, ensuring that temperature and air quality remain within desired parameters.

In summary, the Honeywell EN2H-0221GE51 R0808 is a sophisticated and reliable solution for HVAC systems. Its user-friendly design, advanced control technologies, compatibility with communication protocols, durability, energy efficiency features, and remote access capabilities make it an outstanding choice for various applications in both commercial and residential scenarios.