Honeywell EN2H-0221GE51 R0808 service manual Operating states, Information Display Condition

Models: EN2H-0221GE51 R0808

1 258
Download 258 pages 27.36 Kb
Page 40
Image 40

 

Operation

 

 

SDC / DHC

 

 

 

 

 

 

 

 

 

 

 

Information

Display

Condition

Remarks

 

Buffer tank

Setpoint/Actual

VO1/2 configured as

Connection of PF1 to

 

temperature at

value

buffer tank loading

associated variable input 1

 

top

 

pump

or 2, VI can no longer be

 

 

 

 

called up

 

 

 

 

 

 

Buffer tank

Setpoint/Actual

VO1/2 configured as

Connection of PF2 to

 

temperature at

value

buffer tank loading

variable input VI1, VI2 or VI3

 

bottom

 

pump

 

 

 

 

 

 

 

Solar collector

Actual value

VO1/2 configured as

Special sensor

 

flow temperature

 

solar tank loading pump

 

 

 

 

 

 

 

Solar tank

Actual value

VO1/2 configured as

 

 

temperature

 

solar tank loading pump

 

 

 

 

 

 

 

Solar collector

Actual value

VO1/2 configured as

Connection of KRLF to

 

return

 

solar tank loading pump

variable input VI1, VI2 or VI3

 

temperature

 

 

 

 

 

 

 

 

 

Solar tank switch-

Actual value

 

Solar loading valve activated

 

over temperature

 

 

 

 

 

 

 

 

5.1.2.7.2Operating states

An operating state inquiry occurs after the information menu is called up by turning the input button anti-clockwise. The following displays appear only under the specified conditions and may not be available (depends on device version).

Information

Display

Condition

Direct heating

 

 

 

Direct heating circuit

 

 

 

circuit operating

 

 

 

specified

status

 

 

 

 

 

 

 

 

Mixed heating

 

Mixed heating circuit 1

circuit 1 operating

 

specified

status

 

 

 

 

Remarks

Heating program: Holiday, Absent Til, Party Til, Auto, Summer, Heating, Red.

Heating, Standby

Switching time program:

P1 (P2, P3) control mode: Day, RED, ECO

Heating program: Holiday, Absent Til, Party Til, Auto, Summer, Heating, Red.

Heating, Standby

Switching time program:

P1 (P2, P3) control mode: Day, RED, ECO

40

EN2H-0221GE51 R0808

Page 40
Image 40
Honeywell EN2H-0221GE51 R0808 service manual Operating states, Information Display Condition

EN2H-0221GE51 R0808 specifications

The Honeywell EN2H-0221GE51 R0808 is a versatile and efficient solution designed to enhance HVAC (Heating, Ventilation, and Air Conditioning) systems in commercial and residential settings. This device stands out in the marketplace due to its robust features, technologies, and characteristics that cater to a variety of applications.

One of the primary features of the EN2H-0221GE51 R0808 is its user-friendly interface, which allows for easy configuration and management. The device is equipped with an intuitive display that provides real-time data, enabling users to monitor system performance at a glance. This functionality not only simplifies operation but also enhances user engagement, making it an ideal choice for both novice and experienced users.

The device employs advanced control technologies, including proportional-integral-derivative (PID) control algorithms. This ensures that the HVAC system operates at optimal efficiency, maintaining the desired temperature while minimizing energy consumption. The precision of the PID control allows for smoother transitions and increased comfort levels within the environment.

Another significant characteristic of the Honeywell EN2H-0221GE51 R0808 is its compatibility with various communication protocols, including Modbus, BACnet, and more. This flexibility facilitates integration with existing building management systems, allowing for comprehensive control over heating and cooling operations. Such interoperability aids in streamlining processes and enhancing system performance.

Durability is also a hallmark of the EN2H-0221GE51 R0808. Constructed with high-quality materials, the device is designed to withstand the rigors of demanding environments. Its sturdy design contributes to longevity and reliability, reducing the need for frequent replacements and maintenance.

Energy efficiency is at the forefront of the Honeywell EN2H-0221GE51 R0808's design. It incorporates features that allow for advanced energy monitoring and reporting, helping users identify potential savings areas. This attention to energy consumption not only promotes sustainability but also leads to significant cost savings over time.

Finally, the EN2H-0221GE51 R0808 supports remote access capabilities, enabling users to control and monitor their systems from anywhere. This feature is particularly beneficial for property managers and business owners, as it allows for swift adjustments and oversight, ensuring that temperature and air quality remain within desired parameters.

In summary, the Honeywell EN2H-0221GE51 R0808 is a sophisticated and reliable solution for HVAC systems. Its user-friendly design, advanced control technologies, compatibility with communication protocols, durability, energy efficiency features, and remote access capabilities make it an outstanding choice for various applications in both commercial and residential scenarios.