EN2H-0221GE51 R0808

51

 

Parameter

20

21

22

23

24

25

26

27

28

29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Programming

Date

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hydraulics

 

 

 

 

 

 

 

 

 

 

Configuration

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjustment of the

 

Locking code for

 

Cooling switch-on

 

 

 

curve for

 

 

 

 

 

 

 

 

 

System parameter

 

real time clock

 

 

 

 

Fault memory 2

emergency

 

 

 

operating level

 

temperature

 

 

 

 

(RTC)

 

 

 

 

 

operation without

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

outside sensor

 

Hot water

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Direct heating

 

 

 

Room control C-

Room control Tn

Holiday control

Room setpoint

 

 

 

 

 

 

 

factor

mode

ramp

 

 

 

 

circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mixed heating

I-part Tn

Actuator runtime

Actuator end

Room control C-

Room control Tn

Holiday control

Room setpoint

 

temperature of

 

 

position function

factor

mode

ramp

 

mixed heating

 

 

circuit 1/2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Modulation of

Modulation of

Modulation of

Modulation of start

Modulation of start

Outside

 

Heating circuit

minimum

Heat generator

 

Heat generator

temperature

Base load offset

 

minimum

temperature limit

 

sample time Ta

adjustment time Tn

runtime

time

power

disable

 

forced discharge

 

 

 

 

 

 

 

 

temperature limit

switching

 

 

 

 

 

 

 

 

 

 

 

differential

 

 

District heating

 

 

 

 

 

 

 

 

 

 

Configuration

 

 

 

 

 

 

 

 

 

 

 

Return increase

 

 

 

 

 

 

 

 

 

 

(heating circuits,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

control paths)

 

 

 

 

 

 

 

 

 

 

 

 

Solar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Solid fuel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Buffer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total flow control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cascading

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data bus

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relay test

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Service functions

Fault messages 1/2

Fault message 20

Reset fault

 

 

 

 

 

 

 

 

 

messages

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensor calibration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SDC / DHC

Operation

Page 51
Image 51
Honeywell EN2H-0221GE51 R0808 service manual Parameter Programming Date Hydraulics Configuration

EN2H-0221GE51 R0808 specifications

The Honeywell EN2H-0221GE51 R0808 is a versatile and efficient solution designed to enhance HVAC (Heating, Ventilation, and Air Conditioning) systems in commercial and residential settings. This device stands out in the marketplace due to its robust features, technologies, and characteristics that cater to a variety of applications.

One of the primary features of the EN2H-0221GE51 R0808 is its user-friendly interface, which allows for easy configuration and management. The device is equipped with an intuitive display that provides real-time data, enabling users to monitor system performance at a glance. This functionality not only simplifies operation but also enhances user engagement, making it an ideal choice for both novice and experienced users.

The device employs advanced control technologies, including proportional-integral-derivative (PID) control algorithms. This ensures that the HVAC system operates at optimal efficiency, maintaining the desired temperature while minimizing energy consumption. The precision of the PID control allows for smoother transitions and increased comfort levels within the environment.

Another significant characteristic of the Honeywell EN2H-0221GE51 R0808 is its compatibility with various communication protocols, including Modbus, BACnet, and more. This flexibility facilitates integration with existing building management systems, allowing for comprehensive control over heating and cooling operations. Such interoperability aids in streamlining processes and enhancing system performance.

Durability is also a hallmark of the EN2H-0221GE51 R0808. Constructed with high-quality materials, the device is designed to withstand the rigors of demanding environments. Its sturdy design contributes to longevity and reliability, reducing the need for frequent replacements and maintenance.

Energy efficiency is at the forefront of the Honeywell EN2H-0221GE51 R0808's design. It incorporates features that allow for advanced energy monitoring and reporting, helping users identify potential savings areas. This attention to energy consumption not only promotes sustainability but also leads to significant cost savings over time.

Finally, the EN2H-0221GE51 R0808 supports remote access capabilities, enabling users to control and monitor their systems from anywhere. This feature is particularly beneficial for property managers and business owners, as it allows for swift adjustments and oversight, ensuring that temperature and air quality remain within desired parameters.

In summary, the Honeywell EN2H-0221GE51 R0808 is a sophisticated and reliable solution for HVAC systems. Its user-friendly design, advanced control technologies, compatibility with communication protocols, durability, energy efficiency features, and remote access capabilities make it an outstanding choice for various applications in both commercial and residential scenarios.