5. Other
Problem | Possible Cause |
|
| Remedy | ||
[1] | Condensate | a) Cabinet Contents | 1. | Loading large volumes | 1. | |
| water overflow. |
|
| of warm, moist, |
| product with plastic wrap. |
|
|
|
| uncovered product. |
|
|
|
| b) Location of Unit | 1. | Unit located near high | 1. | Relocate. |
|
|
|
| humidity source such |
|
|
|
|
|
| as fryer, steamer, etc. |
|
|
|
| c) Seals | 1. | Poor sealing around | 1. | Adjust or replace. |
|
|
|
| evaporator, door/ |
|
|
|
|
|
| drawer gaskets. |
|
|
|
| d) Environment | 1. | Extreme environment | 1. | Adjust conditions. |
|
|
|
| and |
|
|
|
|
|
| conditions. |
|
|
|
| e) Rail Condensate Pan | 1. | Overflowing. | 1. | Empty and clean rail |
|
|
|
|
|
| condensate pan. |
[2] | Abnormal Noise | a) Fasteners | 1. | Loose fasteners allow | 1. | Tighten fasteners. |
|
|
|
| vibration of part. |
|
|
|
| b) Compressor | 1. | Problem with mount. | 1. | Properly mount |
|
|
|
|
|
| compressor. Replace any |
|
|
|
|
|
| missing grommets. |
|
|
| 2. Floodback to | 2. Check for signs of | ||
|
|
|
| compressor. |
| floodback to compressor. |
|
|
|
|
|
| Recover, evacuate, and |
|
|
|
|
|
| recharge if necessary. |
|
|
| 3. Defective. | 3. Replace. | ||
|
| c) Fan | 1. | Fan blade loose. | 1. | Adjust and tighten. |
|
|
| 2. Defective motor. | 2. Replace. | ||
|
| d) Relay | 1. | Chattering. | 1. | Replace. |
|
| e) Liquid Line Valve | 1. | Loose. | 1. | Tighten. |
|
| Solenoid |
|
|
|
|
38