5. Other
| Problem | Possible Cause | 
 | 
 | Remedy | ||
| [1] | Condensate | a) Cabinet Contents | 1. | Loading large volumes | 1. | |
| 
 | water overflow. | 
 | 
 | of warm, moist, | 
 | product with plastic wrap. | 
| 
 | 
 | 
 | 
 | uncovered product. | 
 | 
 | 
| 
 | 
 | b) Location of Unit | 1. | Unit located near high | 1. | Relocate. | 
| 
 | 
 | 
 | 
 | humidity source such | 
 | 
 | 
| 
 | 
 | 
 | 
 | as fryer, steamer, etc. | 
 | 
 | 
| 
 | 
 | c) Seals | 1. | Poor sealing around | 1. | Adjust or replace. | 
| 
 | 
 | 
 | 
 | evaporator, door/ | 
 | 
 | 
| 
 | 
 | 
 | 
 | drawer gaskets. | 
 | 
 | 
| 
 | 
 | d) Environment | 1. | Extreme environment | 1. | Adjust conditions. | 
| 
 | 
 | 
 | 
 | and  | 
 | 
 | 
| 
 | 
 | 
 | 
 | conditions. | 
 | 
 | 
| 
 | 
 | e) Rail Condensate Pan | 1. | Overflowing. | 1. | Empty and clean rail | 
| 
 | 
 | 
 | 
 | 
 | 
 | condensate pan. | 
| [2] | Abnormal Noise | a) Fasteners | 1. | Loose fasteners allow | 1. | Tighten fasteners. | 
| 
 | 
 | 
 | 
 | vibration of part. | 
 | 
 | 
| 
 | 
 | b) Compressor | 1. | Problem with mount. | 1. | Properly mount | 
| 
 | 
 | 
 | 
 | 
 | 
 | compressor. Replace any | 
| 
 | 
 | 
 | 
 | 
 | 
 | missing grommets. | 
| 
 | 
 | 
 | 2. Floodback to | 2. Check for signs of | ||
| 
 | 
 | 
 | 
 | compressor. | 
 | floodback to compressor. | 
| 
 | 
 | 
 | 
 | 
 | 
 | Recover, evacuate, and | 
| 
 | 
 | 
 | 
 | 
 | 
 | recharge if necessary. | 
| 
 | 
 | 
 | 3. Defective. | 3. Replace. | ||
| 
 | 
 | c) Fan | 1. | Fan blade loose. | 1. | Adjust and tighten. | 
| 
 | 
 | 
 | 2. Defective motor. | 2. Replace. | ||
| 
 | 
 | d) Relay | 1. | Chattering. | 1. | Replace. | 
| 
 | 
 | e) Liquid Line Valve | 1. | Loose. | 1. | Tighten. | 
| 
 | 
 | Solenoid | 
 | 
 | 
 | 
 | 