Alarm

Priority

Problem

Reset, Corrections, and Adjustments

Signal

 

 

High Condenser Temperature Alarm

Turn the power off, then back on.

 

 

(clogged filter)

 

 

 

 

Condenser and/or air filter dirty. Fan motor not

E7

6

Condenser temperature is outside of

turning. Possible restriction in refrigeration system.

 

 

normal operating temperature. 140°F

 

 

 

(60°C)

Failure to take action when this alarm activates

 

 

 

could result in damage to the compressor.

 

 

Defrost Thermistor Malfunction Alarm

After replacing defrost thermistor, alarm resets.

E8

3

 

 

 

 

Defrost thermistor shorted or open.

 

 

 

Condenser Thermistor Malfunction

After replacing condenser thermistor, alarm resets.

E9

4

Alarm

 

 

 

 

 

Condenser thermistor shorted or open.

 

 

 

EEPROM Write Alarm

After replacing control board, alarm resets.

EA

2

 

 

 

 

Control board has failed.

 

 

 

EEPROM Verification or Read Alarm

After replacing control board, alarm resets.

ED

1

 

 

 

 

Control board has failed.

 