10)Cut the leads of the Solenoid allowing enough lead length to reconnect using closed end connectors.
11)Connect the new Solenoid leads.
12)Attach the Solenoid to the valve body, and secure it with a screw.
13)Replace the panels in their correct positions.
14)Turn on the power supply.
7.REMOVAL AND REPLACEMENT OF EVAPORATOR IMPORTANT
Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repairs or replacement have been made.
1)Turn off the power supply.
2)Remove the panels and the Top Insulation over the Evaporator.
3)Recover the refrigerant and store it in an approved container.
4)Remove the Spray Tubes and the Insulations at the “U” shaped notch where the refrigeration tubings go through the molded chassis.
5)Remove the Insulation Tube, and disconnect the Evaporator Inlet Tubing at the Tee next to the Expansion Valve.
6)Lift up the Evaporator, and disconnect the Evaporator Outlet Tubing.
7)Install the new Evaporator.
8)Install the new Drier.
9)Check for leaks using nitrogen gas (140 PSIG) and soap bubbles.
10)Evacuate the system, and charge it with refrigerant. For
48