Hoshizaki KM-1300MWH, KM-1300MAH, KM-1300MRH service manual Removal And Replacement Of Drier

Models: KM-1300MRH KM-1300MAH KM-1300MWH

1 62
Download 62 pages 15.83 Kb
Page 45
Image 45
4. REMOVAL AND REPLACEMENT OF DRIER

14)Check for leaks using nitrogen gas (140 PSIG) and soap bubbles.

15)Evacuate the system, and charge it with refrigerant. For air-cooled and water-cooled models, see the Nameplate for the required refrigerant charge. For remote air-cooled models, see the Charge Label in the machine compartment.

16)Connect the Terminals, and replace the Terminal Cover in its correct position.

17)Replace the panels in their correct positions.

18)Turn on the power supply.

4. REMOVAL AND REPLACEMENT OF DRIER

IMPORTANT

Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made.

1)Turn off the power supply.

2)Remove the panels.

3)Recover the refrigerant and store it in an approved container.

4)Remove the Drier.

5)Install the new Drier, with the arrow on the Drier, in the direction of the refrigerant flow. Use nitrogen gas at the pressure of 3 - 4 PSIG when brazing the tubings.

6)Check for leaks using nitrogen gas (140 PSIG) and soap bubbles.

7)Evacuate the system, and charge it with refrigerant. For air-cooled and water-cooled models, see the Nameplate for the required refrigerant charge. For remote air-cooled models, see the Charge Label in the machine compartment.

8)Replace the panels in their correct positions.

9)Turn on the power supply.

45

Page 45
Image 45
Hoshizaki KM-1300MWH, KM-1300MAH, KM-1300MRH service manual Removal And Replacement Of Drier