Hoshizaki KM-1300MRH, KM-1300MWH, KM-1300MAH service manual Removal And Replacement Of Fan Motor

Models: KM-1300MRH KM-1300MAH KM-1300MWH

1 62
Download 62 pages 15.83 Kb
Page 53
Image 53
12. REMOVAL AND REPLACEMENT OF FAN MOTOR

10)Secure the insulation using the Plastic Cable Ties.

11)Connect the Thermistor leads through the bushing of the Control Box to the K3 Connector on the Controller Board.

Note: Do not cut the leads of the Thermistor while installing it.

12)Replace the Control Box Cover and the panels in their correct positions.

13)Turn on the power supply.

12. REMOVAL AND REPLACEMENT OF FAN MOTOR

Note: When replacing a Fan Motor with defective winding, it is recommended that a new capacitor be installed.

1)Turn off the power supply.

2)Remove the panels.

3)Remove the Junction Box Cover from the remote condenser unit (Remote Air-cooled model).

4)Remove the closed end connectors from the Fan Motor leads.

5)Remove the Fan Motor Bracket and Fan Motor.

6)Install the new Fan Motor, and replace the removed parts in the reverse order of which they were removed.

7)Replace the panels in their correct positions.

8)Replace the Junction Box Cover in its correct position (Remote Air-cooled model).

9)Turn on the power supply.

53

Page 53
Image 53
Hoshizaki KM-1300MRH, KM-1300MWH, KM-1300MAH service manual Removal And Replacement Of Fan Motor