Hoshizaki KM-1300MRH, KM-1300MWH, KM-1300MAH 12Replace the panels in their correct positions

Models: KM-1300MRH KM-1300MAH KM-1300MWH

1 62
Download 62 pages 15.83 Kb
Page 47
Image 47
12)Replace the panels in their correct positions.

12)Replace the panels in their correct positions.

13)Turn on the power supply.

6.REMOVAL AND REPLACEMENT OF HOT GAS VALVE AND LINE VALVE

IMPORTANT

Always use a copper tube of the same diameter and length when replacing the hot gas lines; otherwise the performance may be reduced.

IMPORTANT

Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made.

1)Turn off the power supply.

2)Remove the panels.

3)Recover the refrigerant and store it in an approved container.

4)Remove the screw and the Solenoid.

5)Disconnect the Hot Gas Valve or Line Valve using brazing equipment.

6)Install the new valve.

CAUTION

Always protect the valve body by using a damp cloth to prevent the valve from overheating. Do not braze with the valve body exceeding 250°F.

7)Install the new Drier.

8)Check for leaks using nitrogen gas (140 PSIG) and soap bubbles.

9)Evacuate the system, and charge it with refrigerant. For air-cooled and water- cooled models, see the Nameplate for the required refrigerant charge. For remote air-cooled models, see the Charge Label in the machine compartment.

47

Page 47
Image 47
Hoshizaki KM-1300MRH, KM-1300MWH, KM-1300MAH service manual 12Replace the panels in their correct positions