Hoshizaki KM-1300MRH, KM-1300MWH, KM-1300MAH service manual aCLEANING PROCEDURE

Models: KM-1300MRH KM-1300MAH KM-1300MWH

1 62
Download 62 pages 15.83 Kb
Page 59
Image 59

[a]CLEANING PROCEDURE

1)Dilute 27 fl. oz. of the recommended cleaner Hoshizaki “Scale Away” or “LIME-A-WAY” (Economics Laboratory, Inc.) with 5 gal. of water.

2)Remove all ice from the Evaporator and the Storage Bin.

Note: To remove cubes on the Evaporator, turn off the power supply and turn it on after 3 minutes. The defrost cycle starts and the cubes will be removed from the Evaporator.

3)Turn off the power supply.

4)Remove the Front Panel and then remove the Insulation Panel, by lifting the panel slightly and pulling it toward you.

5)Drain the Water Tank by removing the Rubber Cap covering the Overflow Pipe in the Water Tank. Remove the Overflow Pipe by turning it counterclockwise.

See Fig. 4.

6)After tank has drained, replace the removed parts in their correct positions.

7)Pour the cleaning solution into the Water Tank.

8)Fully open the Cleaning Valve on the left side wall of the machine compartment.

9)Move the Control Switch, on the Control Box, to the “WASH” position.

10)Replace the Insulation Panel and the Front Panel in their correct positions.

Note: When placing the Insulation Panel, do not catch the hose between the panel and the body.

11)Turn on the power supply, and start the washing process.

12)Turn off the power supply after 30 minutes.

13)Remove the Front Panel and the Insulation Panel.

14)Drain the Water Tank. (See the above step 5).

15)Replace the tubing and the Insulation Panel in their correct positions.

16)Move the Control Switch to the “ICE” position.

59

Page 59
Image 59
Hoshizaki KM-1300MRH, KM-1300MWH, KM-1300MAH service manual aCLEANING PROCEDURE