Hoshizaki KM-1300MRH Drain Timer, Setting, Dip Switch, seconds, T1 Time to drain the Water Tank

Models: KM-1300MRH KM-1300MAH KM-1300MWH

1 62
Download 62 pages 15.83 Kb
Page 23
Image 23
3) Drain Timer

3) Drain Timer

The Drain Timer is factory-adjusted, and no adjustment is required.

SETTING

 

TIME

Dip Switch

Dip Switch

 

 

No. 3

No. 4

T1

T2

OFF

OFF

10 seconds

150 seconds

ON

OFF

10 seconds

180 seconds

OFF

ON

10 seconds

120 seconds

ON

ON

20 seconds

180 seconds

T1: Time to drain the Water Tank

T2: Time to restrain defrost completion

4) Drain Counter

CAUTION

Do not adjust the Drain Counter, or the Evaporator may freeze up.

The Drain Counter is factory-adjusted to drain the Water Tank every 10 cycles, and no adjustment is required. However, where water quality is bad and the icemaker needs a pump drain more often, the Drain Counter can be adjusted as shown in the table below:

SETTING

 

FREQUENCY

Dip Switch

Dip Switch

 

No. 5

 

No. 6

 

OFF

 

OFF

every cycle

ON

 

OFF

every 2 cycles

OFF

 

ON

every 5 cycles

ON

 

ON

every 10 cycles

23

Page 23
Image 23
Hoshizaki KM-1300MRH Drain Timer, Setting, Dip Switch, seconds, T1 Time to drain the Water Tank, Drain Counter, Frequency