5) Freeze Timer

CAUTION

Adjust to proper specification, or the unit may not operate correctly.

Two new dip switches numbered 9 and 10 have been added to the improved “E” board to better prevent possible freeze ups. These settings come factory set to the default setting of 60 min. (OFF, OFF). Check the adjustment chart published in the Tech Specs for proper settings. If the old board does not have these two dip switches, (only 8 in- stead of 10), leave setting as OFF, OFF.

SETTING

 

TIME

Dip Switch

Dip Switch

 

No. 9

 

No. 10

 

OFF

 

OFF

60 min.

ON

 

OFF

70 min.

OFF

 

ON

50 min.

ON

 

ON

60 min.

6) Bin Control

CAUTION

When the ambient temperature is below 45°F, the Bin Control Thermostat operates to stop the icemaker even if the Ice Storage Bin is empty. When the Thermostat is set in the prohibited range, the icemaker operates continuously even if the Ice Storage Bin is filled with ice. Setting in the prohibited range might cause severe damage to the icemaker resulting in failure.

No adjustment is required under normal use, as the Bin Control is factory-adjusted. Adjust it, if necessary, so that the icemaker stops automatically within 10 seconds after ice contacts the Bin Control Thermostat Bulb.

[e] CHECKING THE CONTROLLER BOARD

1)Visually check the sequence with the icemaker operating.

2)Visually check the Controller Board by using the following procedures.

(i)Adjust the Defrost Timer to minimum position.

Disconnect the Thermistor from the Controller Board.

Connect a 1.5 k- 3.5 kresistor to the Connector K3 (pins #1 and #2), and energize the unit.

24

Page 24
Image 24
Hoshizaki KM-1300MWH, KM-1300MAH, KM-1300MRH service manual Checking the Controller Board