Hoshizaki KM-1300MRH, KM-1300MWH, KM-1300MAH service manual 2nd Cycle and after with no pump drain

Models: KM-1300MRH KM-1300MAH KM-1300MWH

1 62
Download 62 pages 15.83 Kb
Page 20
Image 20
2nd Cycle and after with no pump drain

2nd Cycle and after with no pump drain

IMPORTANT

Freeze cycle time is limited to 60 minutes even if Float Switch does not open.

1.Float Switch opens and signals to complete freeze cycle.

4.After the first 5 minutes in freeze cycle. Ready to complete freeze cycle when Float Switch circuit opens.

IMPORTANT

Board never accepts freeze completion signal within the first 5 minutes in freeze cycle.

2.Thermistor reads 48°F. Defrost Timer starts counting.

IMPORTANT

Water Valve opening is limited to 6 minutes.

3.Defrost Timer stops counting.

Defrost cycle is completed and freeze cycle starts.

IMPORTANT

1.Board never accepts defrost completion signal within the first 2 minutes in defrost cycle.

2.Defrost cycle time is limited to 20 minutes even if Defrost Timer does not stop counting.

20

Page 20
Image 20
Hoshizaki KM-1300MRH, KM-1300MWH, KM-1300MAH service manual 2nd Cycle and after with no pump drain