Cabling and Technology Information

Twisted-Pair Cable/Connector Pin-Outs

Crossover Twisted-Pair Cable for

10 Mbps or 100 Mbps Network Connection

The Auto-MDIX operation of the 10/100 ports on the switch also allows you to use crossover cables for all network connections, to PCs, servers or other end nodes, or to hubs or other switches.

If any of these ports are given a fixed configuration, for example 100 Mbps/ Full Duplex, the ports operate as MDI-X ports, and crossover cables must be then used for connections to hubs or switches or other MDI-X network devices.

Cable Diagram

Information

Technology and Cabling

N o t e

Pins 1 and 2 on connector “A” must be wired as a twisted pair to pins 3 and 6

 

on connector “B”.

 

Pins 3 and 6 on connector “A” must be wired as a twisted pair to pins 1 and 2

 

on connector “B”.

 

Pins 4, 5, 7, and 8 are not used in this application, although they may be wired

 

in the cable.

 

 

Pin Assignments

Switch End (MDI-X)

Hub or Switch Port, or Other

 

 

MDI-X Port End

 

 

 

 

Signal

Pins

Pins

Signal

 

 

 

 

receive +

1

6

transmit -

receive -

2

3

transmit +

transmit +

3

2

receive -

transmit -

6

1

receive +

 

 

 

 

B-7