Installing the Switch
Installation Procedures
The following illustration shows an example of connectivity between an RPS/ EPS device and six switch devices as a redundant AC power supply.
RPS port 1
highest priority
RPS port 6
lowest priority
600 RPS/EPS2610-PWR switchesFigure 2-14. Connecting a 600 RPS/EPS to multiple 2610s RPS
Switch the Installing
The 600 RPS/EPS can provide backup power for up to six switches. The 600 RPS/EPS can supply power to only one connected and failed switch at a time. In the illustration above, the switch connected to RPS port 1 has the highest priority and the switch connected to RPS port 6 has the lowest priority. When multiple switches fail, a switch connected to a higher priority port always receives power before a switch connected to a lower priority port.