care and maintenance

8Connect the ADF connector to the scanner, and then connect the power cord to the scanner.

9Use the ADF to scan up to five documents. View the results. If streaks still exist on the scanned images, call HP Customer Support. It may be necessary to order a new clear ADF window/optic assembly (C9915- 60011).

clean the feed-roller assembly manually

1Open the hatch, and then lift the green tab to the fully open position. The feed-roller assembly should be in a nearly vertical position.

Lift the green tab to expose the feed rollers

2Use an HP ADF cleaning cloth (C9915-60056) to clean each of the feed rollers and the small rubber pad that is located below the rollers.

Note: If you do not have the HP ADF cleaning cloth, use a lint-free cloth that has been dampened with isopropyl alcohol.

3Wipe the area around the small rubber pad to remove any paper dust.

4Lower the green tab and feed-roller assembly.

5Close the hatch

maintain the ADF

If misfeeds are occurring frequently follow these steps:

1Clean the feed-roller assembly manually. See clean and maintain the ADF.

2See the online Help for information about resolving ADF problems.

3If the misfeeds continue, order and install the ADF Roller Replacement kit (C9937-68001). The ADF Roller Replacement kit contains a roller mechanism, a separation pad, new screws for the separation pad and replacement instructions (see order maintenance supplies for more information).

order maintenance supplies

You can purchase maintenance parts online at www.hp.com/support/ scannersupplies. Items such as HP ADF cleaning cloths or the ADF Roller Replacement kit are available for worldwide delivery.

user’s manual