image=vmlinuz-2.6.18-92.el5xen vmm=xen.gz-2.6.18-92.el5 label=HP

#Corresponds to kernel 2.6.18-92.el5xen initrd=HP-initrd-2.6.18-92.el5xen.img read-only root=/dev/VolGroup00/LogVol00 append="-- rhgb quiet"

3.Reboot the server.HP System Management Homepage Session Time-out Error

The default value of the ui-timeoutoption in the HP SMH is 20 seconds. For servers with numerous devices, 80 CPUs for example, the home or device pages may take more than 20 seconds to load and you may encounter a timeout message in your browser. You can avoid this by setting the value of ui-timeoutto the maximum of 80 seconds, using one of the following methods:

NOTE: The maximum value for ui-timeoutis 3600 seconds.From the command line:1.Set ui-timeoutto 80 seconds:#/opt/hp/hpsmh/sbin/smhconfig --ui-timeout=802.Restart HP SMH:#/etc/init.d/hpsmhd restartFrom HP SMH :1.Sign in to HP SMH.2.Select SettingsSMHSecurityTimeouts.3.Modify the UI timeout (seconds) value, and then click Apply.4.Sign out of HP SMH.5.Restart HP SMH:# /etc/init.d/hpsmhd restart

HP SAS Integrated Raid (IR) Configuration Utility May Cause Kernel Panics on RHEL4U7

The Integrated Raid (IR) Configuration Utility, cfggen, is a Linux command line utility that configures the IR functionality of the HP Serial Attached SCSI (SAS) controllers that are used in LSI-1068-based HP SAS controllers. The cfggen utility causes kernel panics when creating volumes with RHEL4U7.

Until this issue is resolved in the MPT driver, HP recommends that you use the EFI executable, cfggen.efi, utility to create volumes.

If cfggen is installed on a system running RHEL4U7, the HP Support Pack installer will remove it.

For information about using the cfggen.efi utility, see the SmartSetup Scripting Toolkit Deployment Guide:

http://www.docs.hp.com/en/5991-6250/

Flashing HP PCIe 2-port 1000Base-T adapter (AD337A) Adapters

The HP PCIe 2-port 1000Base-T adapter (AD337A) with the 3.0.48 firmware version cannot be flashed using HP Smart Setup.

58 Known Issues