with the following line:

auth

required

pam_succeed_if.so quiet_success user ingroup sfcb

3.Restart SFCB by entering the following:

# /etc/init.d/sfcb startHP Insight Management WBEM Providers Information Reporting

HP Insight Management WBEM Providers do not currently report all information about bonded network interfaces. If bonded interfaces are configured on a given server, CIM_IPProtocolEndpoint WBEM instances will not be displayed on these servers. This information will be available on servers when the HP Insight Management WBEM Providers add Ethernet teaming support the next release.

Changing IP Address of Network Interface

While HP Insight Management WBEM Providers are running, if the IP address of a network interface is changed the providers do not pickup the new IP address of the network interface. This issue will be resolved in the next release.

Until this issue is resolved, use the following workaround:

Restart the cimserver using one of the following commands as the root user:

If running Pegasus on RedHat Enterprise Linux 5 (RHEL5) or SuSE Linux Enterprise Server

10 (SLES10) enter the following:

#/etc/init.d/tog-pegasus restart

If running SFCB on SuSE Linux Enterprise Server (SLES11), enter the following:

#/etc/init.d/sfcb restartConfiguring Storage Adapters

The Configure Storage Adapters function in the HP Smart Setup EBSU utility requires that the EFI driver for the storage adapter be installed prior to configuring storage adapters. You must first select the Maintain Firmware function from the HP Smart Setup EBSU main menu to upgrade the adapters, thus installing the EFI driver. You can then proceed to use the Configure Storage function to set up your storage adapter.

Partitioning Fibre Channel HBA Adapters

Creating a partition using EBSU, or other partitioning tools, can result in the duplication of the created partition in multiple LUNs. Typically, this happens when there are redundant paths to the same storage device. For example, when you have two paths (A and B) to a storage device then two blocks bound to the original LUN are created. If you create a partition in the original LUN, it will be mirrored in the duplicated blocks.

For more details regarding configuring LUNs, see the HP StorageWorks: Booting Windows Server

2003 for Itanium-based systems from a storage area network application notes:

http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00193929/c00193929.pdf.

To configure the boot LUN, see the “Configuring the HBAs“ section in conjunction with the “Cabling options for single-channel HBAs” section to create a zone/boot environment with only one LUN mapped to the boot HBA.

Installing the MPT Fusion HBA Driver on RHEL 5U2 and RHEL 5U3 using a Xen Kernel Hangs the Server

After the MPT Fusion HBA driver is installed on a system running RHEL 5U2 using a Xen kernel, the server hangs during rebooting and the following messages are displayed: