Maintenance and Diagnostic Tests

The FC 16B does not require any regular physical maintenance, and is designed to minimize the chance of failure, including diagnostic tests and field-replaceable units.

Diagnostic tests are provided to help troubleshoot the hardware and the firmware. The diagnostic tests provided on the switch include tests of internal connections and circuitry, fixed media, and any SFP modules and fiber optic cables in use. The tests are implemented by command, either through a telnet session or through a terminal set up for a serial connection to the switch. Some tests require the ports to be connected by external cables, to allow diagnostics to verify the serializer/deserializer interface, as well as the attached SFP and cable.

All diagnostic tests are run at link speeds of both 1 Gbps and 2 Gbps. For detailed information about the specific diagnostic tests and how to run them, refer to the Fabric OS Procedures Guide.

Test

Command

Description

 

 

 

Error Log

errDump

Displays the error log without

 

 

page breaks.

 

 

 

Switch Offline

switchDisable

Sets the switch to offline state

 

 

necessary to run certain switch

 

 

diagnostics.

 

 

 

Memory Test

ramTest

Checks CPU RAM memory. Run

 

 

offline or online.

 

 

 

Port Register

portRegTest

Checks that the registers and static

Test

 

memory in each ASIC can be

 

 

successfully accessed. Run

 

 

offline.

 

 

 

Central Memory

centralMemoryTest

Checks that the central memory in

Test

 

each ASIC can be successfully

 

 

accessed. Run offline.

 

 

 

Control Message

cmiTest

Verifies that control messages can

Interface (CMI)

 

be sent from ASIC to ASIC.

Conn Test

 

Run offline.

 

 

 

32