Configuring Supported Devices

HP Surestore Director FC-64 Switch

The FC 16B switch can be used with the HP Surestore Director FC-64 switch. Specific configurations must be set on both devices to make this work.

On the FC 16B, logon to the switch with administrative privileges and enter the following telnet commands:

1.switchDisable

2.interopMode 1

3.switchEnable

On the Director FC-64 switch, the following steps must be completed to configure the switch for interoperability:

Step 1: Verify Unique Domain IDs

Step 2: Select a Single Surestore FC-64 Director as Principal Switch

Step 3: Verify Unique Zone Names

Step 4: Verify Brocade Product Zoning Configurations

Step 5: Verify Zone Naming Conventions

Step 6: Verify Operating Mode

Step 7: Verify Surestore FC-64 Director Switches’ Operating

Parameters

Step 8: Verify Firmware Version

Step 9: Verify EFC Manager Version

Step 10: Verify Private Loop Targets on Brocade Products are

Translated to Fabric

Step 11: Add Switches to Fabric

Step 12: Complete Zoning Activities

Step 13: Save Active Zone Set

For complete instructions on configuring the HP Director FC-64 switch see “Checklist for Merging Fabrics” in the Merging Heterogeneous Fabrics Instructions white paper on the FC 16B documentation CD-ROM.

Setup

25

Page 31
Image 31
HP A7340-96002 manual Configuring Supported Devices, HP Surestore Director FC-64 Switch