Specification

Description

 

 

Modes of

Fibre Channel Class 2 and Class 3

operation

 

 

 

Aggregate

64 Gbps if all 16 ports running at 2 Gbps, full duplex

switch I/O

 

bandwidth

 

 

 

Frame buffers

27 buffers per E_Port and 16 buffers per F_Port at 2112

 

bytes per frame

 

 

Port to port

Less than 2 microseconds with no contention (destination

latency

port is free)

 

 

Data

Up to 500 m (1,625 ft.) for short-wavelength optical link

transmission

Up to 10 km (32,820 ft.) for long-wavelength optical link

range

 

 

 

Chassis type

Forced-air cooling that flows from the power supply side

 

to the SFP media side

 

 

Environmental

The following table lists the acceptable environmental ranges.

Condition

Acceptable Range

 

 

Temperature (operating)

10°C to 40°C

 

 

Temperature (non-operating)

-35°C to 65°C

 

 

Humidity (operating)

5% to 85% RH non-condensing, at 40°C

 

 

Humidity (non-operating)

0% to 90% RH non-conducting, at 40°C

 

 

Altitude (operating)

0 to 3 kilometers above sea level

 

 

Altitude (non-operating)

0 to 12 kilometers above sea level

 

 

Shock (operating)

4 G, 11 MS duration, half sine

 

 

Shock (non-operating)

20 G, 11 MS duration, sq. wave

 

 

Vibration (operating)

5 G, 0-3 kHz at 1.0 octave/minute

 

 

36

Quick Start Guide

Page 42
Image 42
HP A7340-96002 manual Environmental