To view Boot ROM accessibility status, use the display startup command. For more information about the display startup command, see the Fundamentals Command Reference.

Follow the step below to disable Boot ROM access:

To do…

Use the command…

Remarks

 

 

Required

Disable Boot ROM access

undo startup bootrom-access

By default, Boot ROM access is

enable

enabled.

 

 

 

Available in user view.

 

 

 

Configuring the detection timer

Some protocols might shut down ports under specific circumstances. For example, MSTP shuts down a BPDU guard enabled port when the port receives a BPDU. Then, the device starts the detection timer. If the port is still down when the detection timer expires, the port quits the shutdown status and resume its actual physical status.

Follow these steps to configure the detection timer:

To do…

Use the command…

Remarks

Enter system view

system-view

 

 

 

 

 

Optional

Configure the detection timer

shutdown-interval time

The detection interval is 30

 

 

seconds by default.

 

 

 

Configuring temperature alarm thresholds (available only on the A3100 v2 EI)

You can set the temperature alarm thresholds to monitor the temperature of a device.

The temperature alarm thresholds include lower temperature limit, warning temperature threshold, and temperature alarming threshold.

When the device temperature drops below the lower limit or reaches the warning threshold, the device logs the event and outputs a log message and a trap.

When the device temperature reaches the alarming threshold, the device constantly outputs log and tap messages to the configuration terminal and lights the temperature alarm LED on the device panel.

Follow these steps to configure temperature alarm thresholds:

To do…

Use the command…

Remarks

Enter system view

system-view

 

 

 

135