IMPORTANT: Provide the SNMP credentials in the WBEM settings section on the System Protocol Settings page (Options > Protocol Settings > System Protocol Settings). Only the WBEM default credentials are passed from HP SIM to HP Storage Essentials. Any default credential information you set up in regards to SNMP is not passed from HP SIM to HP Storage Essentials.
1.Change the discovery setting for McDATA and Connectrix switches to SNMP following the steps in ”Changing the Discovery Settings” on page 130.
2.Verify the following on the proxy and the switches accessible from the proxy:
•The SNMP agent is enabled.
•The
3.To discover the proxy, enter the following information in HP SIM:
•IP address or system name of the EFC Manager or Connectrix Manager you want to discover.
•User name. The default user name, which is public (the
•Enter anything as a password; HP SIM does not allow an empty password field.
4.Make sure there are no port conflicts for receiving SNMP traps. When the management server is configured to contact the proxy by SNMP, it receives events from the proxy in the form of SNMP traps. By default, the management server uses port 162 to receive SNMP traps. If another software package is using that port, the management server is unable to receive the traps. For information about changing the port, see ”Changing the SNMP Trap Listener Port and Community String for Switches Discovered with SNMP” on page 133.
5.Set up the proxy to send traps to the correct port. When you are using the SNMP setting to discover a proxy, you must configure the SNMP agent on the proxy manager to send traps from all switches managed by the proxy to the management server using the port you selected. For more information, see the documentation for your proxy.
NOTE: The management server uses the Windows SNMP trap service when you run HP SIM and HP Storage Essentials on a Windows server or when the property cimom.winsnmpTrapService=true is set. The Windows SNMP trap service is not used on Solaris servers.
Discovering McDATA and Connectrix Switches through a Direct Connection and SNMP
The management server uses
To discover a McDATA or Connectrix switch directly:
HP Storage Essentials SRM 6.0 Installation Guide 129