Diagnostic Messages

Warning Messages

The value ACCESS=0x2c should be used for all code or read-only subspaces and the value ACCESS=0x1f should be used for all data or read-write subspaces.

45MESSAGE Previous value for .SHLIB is being changed to this value

CAUSE

More than one .SHLIB directive was

 

encountered.

ACTION

Remove the extra .SHLIB

 

directive(s).

46MESSAGE The +DA option conflicts with the .LEVEL directive, using

.LEVEL %s.

CAUSE

The assembly source file contained a

 

.LEVEL directive which conflicted

 

with the command-line +DA option.

 

The assembler always honors the

 

.LEVEL directive found in the source

 

file. The command-line +DA was

 

ignored.

ACTION

Remove +DA from the command-line

 

used to invoke the assembler.

47MESSAGE The behavior of instruction %s is undefined with the operands and completers supplied.

CAUSE

The behavior of the instruction used

 

is undefined with the operands

 

supplied.

ACTION

Read the PA-RISC Architecture

 

manual entry for the instruction

 

being used, paying attention to the

 

cases in which the behavior of the

 

instruction is undefined. Recode the

 

operands for the instruction so that

 

the operands don't cause the

 

instruction to be undefined.

152