Diagnostic Messages

 

 

Error Messages

 

 

value for the month,

 

 

(Jan=1,…Dec=12) and yyyy is the

 

 

year.

 

ACTION

Change the parameter to .SHLIB to a

 

 

valid value.

1088

MESSAGE

Floating point register %s is

 

 

out of range for %s,SGL

 

CAUSE

The floating-point register used is not

 

 

valid for this opcode. The multiops

 

 

FMPYADD,SGL and FMPYSUB,SGL

 

 

require that the operands be single

 

 

precision floating-point registers in

 

 

the range %fr16L,%fr16R ..

 

 

%fr31L,%fr31R. Specifying a

 

 

register below %fr16 will result in

 

 

this error message.

 

ACTION

You must use single precision

 

 

floating-point registers in the range

 

 

%fr16L,%fr16R ..

 

 

%fr31L,%fr31R when using single

 

 

precision FMPYADD or FMPYSUB.

1089

MESSAGE

Revision level must be

 

 

specified for .LEVEL

 

 

directive

 

CAUSE

A .LEVEL directive was missing an

 

 

architecture level value.

 

ACTION

You must specify a valid architecture

 

 

level of 1.0, 1.1, or 2.0.

1090

MESSAGE

Value of %1s must be in the

 

 

range

 

 

[%2s..%3s]

 

CAUSE

The immediate value %1s is

 

 

constrained to be in the range

 

 

%2s..%3s for the current instruction.

 

ACTION

Use a different instruction that

 

 

allows for a larger range, or use a

 

 

register to hold the value %1s.

Chapter 8