Diagnostic Messages

Error Messages

 

ACTION

Remove the duplicate .CALLINFO

 

 

directive or correct the location of the

 

 

.PROC and .PROCEND directives for

 

 

this procedure.

1031

MESSAGE

Value for %s must be >=0

 

CAUSE

1. In a .CALLINFO directive the

 

 

parameter FRAME is assigned a

 

 

negative value. 2. In .BLOCK or

 

 

.BLOCKZ directive the parameter is a

 

 

negative value.

 

ACTION

Supply a non-negative value.

1032

MESSAGE

Value for %s must be in range

 

 

%r3..%r18

 

CAUSE

In a .CALLINFO directive the

 

 

parameter ENTRY_GR is assigned an

 

 

invalid general register.

 

ACTION

Use a general register in the range

 

 

%r3 to %r18 when assigning to the

 

 

parameter ENTRY_GR.

1033

MESSAGE

Value for %s must be in range

 

 

%fr12..%fr21

 

CAUSE

In a .CALLINFO directive the

 

 

parameter ENTRY_FR is assigned an

 

 

invalid floating-point register.

 

ACTION

Use a floating-point register in the

 

 

range %fr12 to %fr21 when

 

 

assigning to the parameter

 

 

ENTRY_FR.

1034

MESSAGE

ENTRY_SR must be %sr3 or not

 

 

specified

 

CAUSE

In a .CALLINFO directive the

 

 

parameter ENTRY_SR specifies an

 

 

invalid space register.

160