T H E O R Y O F O P E R A T I O N

Signal

Signal Name

Signal

Operation

Mnemonic

Level

 

 

 

 

 

 

CLEAR

Remote clear

Low

Clears the input buffer.

 

 

 

 

 

 

 

Resets the plotter and re-initializes

RESET

Remote Reset

Low

all logic while the signal is asserted.

Ready remains high while reset is

 

 

 

 

 

 

asserted.

 

 

 

 

 

 

 

Terminates the buffer data currently

 

 

 

being loaded, causes all previously

 

 

 

loaded data to be output in sequence,

RLTER

Remote line

Low

then outputs the buffer data just

terminate

terminated in sequence. This

 

 

 

 

 

command is ignored if received

 

 

 

immediatley after a full scan has

 

 

 

been automatically terminated.

 

 

 

 

RFFED

Remote form

Low

 

feed

 

 

 

 

 

 

 

Terminates the buffer data currently

 

 

 

 

Remote end

 

being loaded, causes all previously

 

 

loaded buffer data to be output in

REOTR

of

Low

sequence, then outputs the buffer

 

transmission

 

 

 

data just terminated in sequence.

 

 

 

 

 

 

Paper is then advanced.

 

 

 

 

Table 5-3. Remote function signals