HP V8.5 manual Byte Line feed, Error Messages

Models: V8.5

1 80
Download 80 pages 41.38 Kb
Page 43
Image 43

4

4-16

O P E R A T I O N

Byte 10:

line feed

0A

Example: To set the plotter to:

contrast=C3

 

 

speed=1.0 ips

 

 

media=LP

 

 

scaling=S2

 

 

emulation=P3

 

 

formfeed=F2

 

 

bytes/scan=b1

 

 

grayscale media table=t1

Then send header: 99 13 21 31 43 53 61 71 81 0A

If the V8.5E accepts the setup string, the display will flash

If there are any errors in the string, such as an out of range value on one of the numbers, or any other errors in the string format, the plotter will not accept the string, no reconfiguration will take place, and the error LED will flash twice.

4.4ERROR MESSAGES

1.MediaOutError: Theplotterwilldisplayasmallsquare,flashing segmentsandtheerrorLEDwillflash.Tofixthiserror,reloadmedia intothepotter.Plottermustbeputbackonlinetocontinueplotting.

2.HotHeadError: TheplotterwilldisplayHtandtheerrorLEDwill flash.Theplotterwilldisplaythiserroruntilthethermalprinthead coolstoatemperaturethatissafetoplotagain.

3.24VoltsError: Theplotterwilldisplay24andtheerrorLEDwill flash.Ifthiserroroccurs,the24voltpowersupplymaybefaulty.Please contact your product representative.

4.ThermistorError: TheplotterwilldisplaytHandtheerrorLEDwill flash.Iftheerroroccurs,thethermalprintheadmaybefaulty.Please contact your product representative.

V8.5eRev2.2.2002

Page 43
Image 43
HP V8.5 manual Byte Line feed, Error Messages