troubleshooting your workstation
screen is blank because the system failed to bootFigure
CAUTION
screen is blank because the system failed to boot
Your workstation’s operating system will fail to boot if the line voltage switch is set to 230V and AC line voltage is 115V.
To solve this problem:
1.Place the workstation so that you are looking at the back of it.
2.Use a small thin bladed screwdriver to slide the workstation’s line voltage switch to the left until you see 115 in the right opening of the switch. See Figure
Slide switch to left to get 115V | Slide switch to right to get 230V | ||
|
|
|
|
|
|
|
|
Line
Voltage
Switch
Power Plug
Connector
Care must be taken to ensure that the line voltage switch is set correctly. Failure to do this could destroy the power supply if the line voltage switch is set to 115V and AC line voltage is 230V.
58 | Chapter 3 |