1 – Amber

2 - Green

3 - Green

Interpretation

 

 

 

 

Flashing 1 Hz

On

Off

An overtemperature

 

 

 

condition exists.

 

 

 

 

Flashing 2 Hz

Flashing 2 Hz

Off

The capacitor pack is not

 

 

 

attached.

 

 

 

 

Flashing 2 Hz

Flashing 2 Hz

On

The capacitor has been

 

 

 

charging for 10 minutes, but

 

 

 

has not reached sufficient

 

 

 

charge to perform a full

 

 

 

backup.

 

 

 

 

On

On

Off

The current backup is

 

 

 

complete, but power

 

 

 

fluctuations occurred during

 

 

 

the backup.

 

 

 

 

On

On

On

The cache module

 

 

 

microcontroller has failed.

 

 

 

 

Hot-plug fans

CAUTION: To avoid damage to server components, fan blanks must be installed in fan bays 1 and 2 in a single-processor configuration.

The only two valid fan configurations are listed in the following table.

Configuration

Fan bay 1

Fan bay 2

Fan bay 3

Fan bay 4

Fan bay 5

Fan bay 6

 

 

 

 

 

 

 

1 processor

Fan blank

Fan blank

Fan

Fan

Fan

Fan

 

 

 

 

 

 

 

2 processors

Fan

Fan

Fan

Fan

Fan

Fan

 

 

 

 

 

 

 

For a single-processor configuration, four fans and two blanks are required in specific fan bays for redundancy. A fan failure or missing fan causes a loss of redundancy. A second fan failure or missing fan causes an orderly shutdown of the server.