6. MENU FUNCTIONS
State a distance that easily exceeds the true distance. The maximum distance that can be stated is
500 metres. Place Automower® in the charging station and select Test OUT
Drive past wire (2-4)
The front of the mower always passes the boundary wire by a specific distance before the mower turns. The default distance is 25 cm, but this can be changed if required.The minimum value is 25 cm and the maximum value is 30 cm.
Now specify the number of centimetres you want the mower to pass the boundary wire and press OK.
6.5 Security (3) |
| |
Through this selection, settings relating to security |
| |
Timer | ||
and the connection between the mower and the | ||
| ||
charging station can be made. |
| |
| Installation | |
Change PIN code |
| |
Enter the new PIN code and press OK. Enter the | Security | |
| ||
same code again and confirm by pressing OK. When |
| |
the PIN code is changed, a message stating that the | Settings | |
PIN code has been changed appears in the display |
| |
momentarily. |
| |
Make a note of the new PIN code on the designated |
| |
line in Memo on page 4. |
|
Change PIN code
Security level
New loop signal
Security levels (3-2)
There are three security levels to choose from: low, medium and high. Low and medium security prohibits access to Automower® if the PIN code is unknown. High security also includes a warning that sounds if the correct PIN code is not entered after a designated time period.
Chainge PIN code
Security level
New loop signal
Low
Medium
High
Function | Low | Medium | High |
|
|
|
|
|
|
|
|
Time lock | X | X | X |
|
|
|
|
PIN request |
| X | X |
|
|
|
|
Alarm |
|
| X |
|
|
|
|
English - 47